Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Brand: Abrahamsen Audio
Packaging: Carton
Productivity: 5000 Units per Month
Transportation: Ocean,Land,Air
Place of Origin: Taiwan, China
Supply Ability: 100 Units per Month
Certificate: ISO90001
HS Code: 85437099
Port: Keelung,Kaoshung
Payment Type: L/C,T/T,Paypal
Incoterm: FOB,CIF,EXW
The AD24-12 & AD24-24 module are a series of isolated, Fly-back digital power supply that operate from a input range 85 to 265VAC (47~63Hz). These digital power supplies are available in a range of output voltage 12V and 24V, continuous 24Watts output capability. They are packaged in an EI-57 standard UL 94V-0 plastic enclosure; plug is 3 prong US type. Standard features include over current and short circuit protection. The efficiency is 80% minimum under 25% to 100% load condition. Typical applications include IT peripheral, home security data access system and other computing and communications equipment.
◊ Home security data access system
◊ Distributed power architectures
◊ Data networking equipment
◊ Telecommunication
◊ Computers and peripherals
◊ Universal input 85 ~265VAC
◊ Output 12/24VDC 0~2A, 24Watts
◊ EI-57 standard package
◊ High efficiency, less power dissipation meet EISA 2007 requirement
◊ Over current ,short circuit & over voltage protection
◊ Design compliant with UL, cUL, GS, CE standard
Output Voltage | Input Range | Max. O/P Current | Typical Efficiency | Model |
12V | 85-265VAC | 2.0A | 84% | AD24-12 |
24V | 85-265VAC | 1.0A | 84% | AD24-24 |
Parameter | Symbol | Min. | Max. | Unit |
Continuous Input Voltage | Vin | 85 | 265 | V |
Operating Temperature | Ta | -20 | 50 | °C |
Storage Temperature | Ts | -40 | 85 | °C |
Operating Humidity*2 | 20% | 80% | RH | |
Storage Humidity | 10% | 90% | RH |
Note:
*1. Use beyond the maximum rating may cause a reliability degradation of the power supply or may permanently damage the unit.
*2. Above humidity range to be defined under Non-condensing status
Parameter | Symbol | Min. | Typ. | Max. | Unit |
Input Voltage | Vin | 85 | 120/230 | 265 | VAC |
Frequency | f | 47 | 50/60 | 63 | Hz |
No Load Input Power | Pi(N.L.) | 0.5 | Watts | ||
Inrush Current*3 | 30/60 | A | |||
Input Current | 1.0 | A |
Note:
*3. The inrush current is measured under normal input voltage (115/230VAC), cold start, 25oC & full load condition
Parameter | Model | Symbol | Min. | Typ. | Max. | Unit |
Output Voltage Set Point | PIP12VDCe PIP24VDCe | Vout | 11.94 23/88 | 12 24 | 12.18 24.36 | V |
Load Regulation*5 | All | % | 1% | |||
Line Regulation*6 | All | % | 1% | |||
Regulation Over Temperature(-20°C to 65°C) | All | TBD | mV | |||
Output Ripple & Noise | All | 150 | mVp-p | |||
Output Current Range | PIP12VDCe PIP24VDCe | Iout | 0 | 2.0 1.0 | A | |
Turn On Time | All | TBD | ms | |||
Overshoot at Turn On | All | 5 | % |
Note:
*4 All specifications are defined under nominal input (120/230VAC), full load at 25 oC unless otherwise specified.
*5 Load regulation: by change the output load from 10% to 100% of rated load carries out the measurement.
*6 Line regulation: by change the line input from specified range, carries out the output measurement. With fixed rated load.
*7 The ripple & noise is measured using 0-20MHz band width oscilloscope & terminated output a 10u/35V tantalum or MLCC X5R capacitor.
Parameter | Model | Symbol | Min. | Typ. | Max. | Unit |
Transient Response*8 | ||||||
ΔV 50% to 100% of Load | All | TBD | mV | |||
Recovering Time | Tr | TBD | μS | |||
ΔV 100% to 50% of Load | TBD | mV | ||||
Recovering Time | Tr | TBD | μS |
*8 di/dt = 0.5A/uS, Ta = 25 oC. with 10u/35V tantalum or MLCC X5R capacitor on output.
Parameter | Model | Symbol | Min. | Typ. | Max. | Unit |
Efficiency*9 | All | η | 85 | % | ||
Switching Frequency | fosc | 65 | KHz | |||
Over Voltage Protection | OVP | 110 | 130 | 150 | % | |
Over Current Protection | OCP | 110 | 145 | 180 | % | |
Short Circuit Protection*10 | SCP | Automatic Recovery | ||||
Mean Time Between Failure*11 | MTBF | 50,000 | Hrs | |||
Indicator | Red LED Shows Output is Powered |
*9. The efficiency η is average efficiency value where η=(η1+η2+η3+η4)/4, η1~η4 means the efficiency value under 25%,50%,75% & 100% load & normal input condition.
*10. When short circuit or over current is activated, the power supply will go into Hiccup mode against short circuit or overload conditions and will recover once fault condition removed.
*11. T ambient at 25oC, rated load condition
◊ EI-57 standard package
◊ Mounting, plug into outlet and is secured with electrical plate mounting screw
◊ Plug 3 prong US
◊ Connection, 3 screw terminals (Positive, Negative, Earth ground)
◊ Weight : 180g typical
Product Categories : Electronics Design and Manufacture Service > A/D Converter
The file is encrypted. Please fill in the following information to continue accessing it
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.